Concept visualization of a generator with optional holding tank and pump
XIAOYA TECHNOLOGY

HOCl output quality
& stability.

Plan for the solution your process needs, from generation to the point of use.

Follow the solution
to where it is used.

An outlet reading describes the sample taken there. If solution is held or distributed, identify the sampling points and the time between generation and use.

A

Generator outlet

Record the operating setting, sample time and agreed output measurements.

B

Holding stage

If included in the system

Record the container, holding conditions and elapsed time.

C

Point of use

Check the delivered solution against requirements agreed for that location and application.

Direct supply: generator outlet to the point of use, without a holding stage.

How will your site
use the solution?

The use pattern determines which holding and delivery conditions need review.

Generate Use

Direct use

Match generation to the operating schedule and verify the solution at the selected use point.

When does the process need solution?

Generate Hold Use

Buffer & distribution

Identify peak demand, holding time and the delivery route. Include low-demand periods when solution may remain longer.

How long will it remain in the system?

Fill Store Use

Container storage

Define the container, closure, environment and intended period of use. A shelf-life statement needs evidence for those conditions.

Which storage conditions will be tested?

Define the conditions.
Then the holding period.

A useful storage specification describes more than a number of days.

Concept illustration of a closed opaque container with a blue closure
Container & contact materials
Vessel, closure, hoses and other materials in contact with the solution.
Light & temperature
The expected environment during storage and delivery.
Opening & handling
How the container is opened, refilled and accessed during use.
Starting condition & time
Initial measurements, generation time and the intended holding period.

Use evidence from representative conditions to set the permitted holding period and re-test requirements.

What does “purity” mean
in your specification?

FAC and pH describe important output characteristics. They do not establish a complete composition profile or the absence of every other substance.

DEFINE

The target

Identify the required output properties and acceptance criteria for the intended use.

SELECT

Relevant analyses

Agree which other constituents need assessment for the feed, generation process and application.

INTERPRET

The analytical limit

Review the method, units and reporting or quantification limit. A result below a limit is not proof of absolute zero.

Build a record that supports
the holding period.

Agree the conditions and acceptance criteria before the study, then compare results on that basis.

  1. Identify the sample

    Equipment, water and feed, operating conditions, sampling location and starting measurements.

  2. Reproduce the conditions

    Representative containers, storage environment and handling practices.

  3. Measure over time

    Agreed sampling intervals, test methods and measurements across the proposed period.

  4. Review against criteria

    Define release, holding, re-test and rejection decisions for that process.

HOCl generator with water preparation and plastic solution storage tank

Turn the use plan into
equipment requirements.

Discuss four decisions with Xiaoya.

Generation schedule
When is solution needed, and how does demand change?
Holding capacity
Is a buffer required, and what holding time will it create?
Delivery arrangement
Where will solution travel, and where should it be sampled?
Monitoring scope
Which checks are manual, and which instruments or controls are required?
Explore integrated systems

Your storage plan.
Your delivery requirements.

Share your application, demand pattern, planned holding period and existing containers or delivery system.

These details help Xiaoya discuss the equipment arrangement and information needed to review it.

Discuss My Storage Setup