SALT-FED · MEMBRANE ELECTROLYSIS

Salt-fed HOCl
generators.

Generate hypochlorous acid solution on site using salt and purified water. Build the equipment scope around your demand.

Salt + purified waterProject-based configuration
visualization based on Xiaoya’s 100 L/h configuration reference
START WITH YOUR REQUIRED OUTPUT

Two documented configurations.
A project-specific choice.

front view based on the XY SAEW-50 training reference

Use these configurations as a starting point. We review required output, solution quality and site conditions together before defining your equipment.

Parameter50 L/h100 L/h
Reference modelXY SAEW-50XY-AEOW 100L
Solution output50 L/h100 L/h
Available chlorine500 mg/L500 mg/L
pH reference5.0–6.5Confirm for the proposed configuration
Inlet pressure0.2–0.3 MPaConfirm for the proposed configuration
Rated power1.3 kW1.5 kW
Cabinet size600 × 520 × 1430 mm800 × 600 × 1600 mm

Explore the 100 L/h equipment configuration →

Need a different output or equipment package?

Tell us your demand and operating schedule. Discuss a tailored configuration with Xiaoya.

Discuss a custom configuration
FROM RAW MATERIALS TO YOUR PROCESS

Plan the generator.
Plan the connections.

The generator is part of a site system. Water preparation, brine preparation, solution storage and delivery are coordinated around the application.

  1. Prepare the water

    Purified water suited to the agreed equipment requirements.

  2. Prepare the brine

    Salt preparation and feed arranged for the selected configuration.

  3. Generate HOCl

    Membrane electrolysis with the specified control package.

  4. Store & deliver

    Coordinate tanks, pumps and delivery to your treatment points.

Agree what is included.

Built-in or external water treatment, brine tanks, storage and delivery equipment depend on the project. Review the supply list and customer-side works before ordering.

EXPLORE THE EQUIPMENT PACKAGE

Look closer at the 100 L/h configuration.

Review the generator, controls, water preparation and storage in one place. Use the detailed configuration to discuss your equipment scope.

View the 100 L/h configuration
CONTROL & MAINTENANCE

A closer look at operation.

Original Xiaoya installation photograph showing ORP, pH instruments and touchscreen

The installed panel and the product visualization show different configurations. Agree the required measurements for the selected configuration. Screen readings are a snapshot, not rated performance.

See the process. Define the controls.

The original installation photo shows a touchscreen with separate pH and ORP displays. Use the configuration discussion to agree the operating interface, measurements and maintenance needs for your site.

  • Operating functionsDiscuss the required controls, monitoring and alarms.
  • Water and feed preparationConfirm the water quality, salt specification and preparation procedure.
  • Routine maintenanceReview cleaning, inspection and replacement parts for the selected package.
A REAL INSTALLATION

Equipment in its working environment.

At our salt-feeding installation in Zibo, we display the main control cabinet and all surrounding on-site auxiliary equipment. This layout shows the complete on-site configuration of the system.

Allow for equipment access, water connections, drainage and routine service when planning your layout.

Xiaoya salt-fed installation in Zibo with surrounding site equipment and pipework
BEFORE YOU REQUEST A PROPOSAL

A few useful answers.

Can I specify 1,000 ppm from these references?

We accept custom orders. If you require a higher concentration, please consult with our sales representative to discuss your specific usage scenarios and operating conditions.

Does this generator need purified water?

The 50 L/h technical reference specifies purified water, and the 100 L/h package includes a pure-water system. Share your source-water information so the preparation equipment can be defined.

How should I compare output and concentration?

Tell us your requirements, and we will evaluate the appropriate output and concentration for your application.

Are the tanks and water-treatment system included?

The scope of supply is subject to the proposal, and we accept custom orders. Please review the equipment list to confirm the generator, water treatment system, storage tanks, water pumps, and the included fittings.Start with your application, required solution volume, operating schedule and destination. Add concentration, pH and site conditions if known. You do not need to select a model before contacting us. You can download the selection chart on the right and submit your requirements.

Can the equipment match our destination power supply?

Tell us the destination voltage, phase and frequency. Xiaoya will review the electrical requirements for your configuration before quoting.

What information should I send first?

Start with your application, required solution volume, operating schedule and destination. Add concentration, pH and site conditions if known. You do not need to select a model before contacting us. You can download the selection chart on the right and submit your requirements.

Contact Xiaoya for specifications and reports for your proposed equipment.

YOUR SALT-FED GENERATOR PROJECT

Start with your application.
We’ll discuss the configuration.

Share your output needs and destination with Xiaoya Group.